| Sr. No. |
Property |
Unit |
Test Method |
Virgin PTFE |
15%
Glass Filled PTFE |
25%
Glass Filled PTFE |
25% Carbon Filled PTFE | 15% Graphite Filled PTFE | 40% Bronze Filled PTFE | 60% Bronze Filled PTFE | 55% Bronze +5% MoS2 | ||||||||
|
1.
|
Density | gm/cc | ASTM D-792 | 2.1-2.2 | 2.23-2.24 | 2.24-2.25 | 2.12-2.14 | 2.14-2.16 | 3.1-3.2 | 3.75-3.8 | 3.8-3.9 | ||||||||
|
2.
|
Tensile Strength | kgf/cm2 | ASTM D-638 | 210-350 | 150-225 | 125-200 | 120-155 | 150-200 | 125-150 | 105-140 | 110-145 | ||||||||
|
3.
|
Elongation of break | % | ASTM D-638 | 250-400 | 225-325 | 200-300 | 100-150 | 175-225 | 100-175 | 80-160 | 90-165 | ||||||||
|
4.
|
Compressive Strength | kgf/cm2 | ASTM D-695 | 40-50 | 65-75 | 75-85 | 75-85 | 65-75 | 85-100 | 115-125 | 115-125 | ||||||||
|
5.
|
Compressive Modulus | kgf/cm2 | ASTM D-695 | 4000 | 6000 | 7000 | 8400 | 8000 | 8500 | 8800 | 8800 | ||||||||
|
6.
|
Deformation
A. 2 Hrs. 23oC
113 kg/cm2 |
%
|
ASTM D-621 | ||||||||||||||||
|
|
|
12 | 10 | 9 | 5 | 6 | 5 | 4 | 4 | ||||||||||
| 15 | 12 | 11 | 7 | 8 | 6 | 5 | 5 | ||||||||||||
| 8 | 7.5 | 7 | 3.5 | 4.5 | 3 | 2.5 | 2.5 | ||||||||||||
| 55 | 52 | 50 | 35 | 43 | 42 | 40 | 40 | ||||||||||||
|
7.
|
Flexural Strength | kgf/cm2 | ASTM D-790 | 57 | 50 | 42 | 96 | 60 | 85 | 80 | 80 | ||||||||
|
8.
|
Flexural Modulus | kgf/cm2 | ASTM D-790 | 3500-6300 | 20000 | 16700 | 11900 | 11000 | 14000 | 13800 | 13500 | ||||||||
|
9. |
Impact strength | cmkgf/cm2 | ASTM D-256 | ||||||||||||||||
| A. -20oC | 9 | 9.25 | 9.5 | 8 | 10 | 11 | 11 | 11 | |||||||||||
| B. +20oC | 15 | 12-5 | 11 | 10 | 14 | 9 | 10 | 10 | |||||||||||
|
10.
|
Hardness | Shore D | ASTM D-2240 | 60-65 | 65-70 | 70-75 | 70-75 | 60-65 | 70-75 | 70-75 | 70-75 | ||||||||
|
11.
|
Coefficient of Friction | ||||||||||||||||||
| A. Dynamic P-7 kg/cm2 V-0.5 m/s | ___ | 0.04-0.06 | 0.31-0.37 | 0.5-0.54 | 0.12-0.17 | 0.11-0.16 | 0.11-0.15 | 0.12-0.16 | 0.01-0.14 | ||||||||||
| B. Static P-35 kg/cm2 | 0.05-0.08 | 0.1-0.12 | 0.11-0.13 | 0.09-0.11 | 0.08-0.10 | 0.08-0.1 | 0.08-0.1 | 0.07-0.09 | |||||||||||
|
12.
|
Water Absorption | % | ASTM D-570 | 0 | 0.015 | 0.013 | 0 | 0 | 0 | 0 | 0 | ||||||||
|
13.
|
Heat Resistance at Atm. Pressure | 0C | ___ | -250 to +260 | -250 to +260 | -250 to +260 | -250 to +260 | -250 to +260 | -250 to +260 | -250 to +260 | -250 to +260 | ||||||||
|
14
|
Thermal Conductivity | 10-4 cal cm SoC | cenco Fitch | 6 | 8 | 9 | 13 | 14 | 17 | 19 | 19 | ||||||||
|
15.
|
Liner Thermal Expansion | % | ASTM D-696 | Axial | Radial | Axial | Radial | Axial | Radial | Axial | Radial | Axial | Radial | Axial | Radial | Axial | Radial | Axial | Radial |
| A. 30-150oC | 1.5 | 1.5 | 1.5 | 1.0 | 1.5 | 0.7 | 1.2 | 1.0 | 1.3 | 1.0 | 1.15 | 0.95 | 1.1 | 0.9 | 1.1 | 0.9 | |||
| B. 30-200oC | 2.4 | 2.3 | 2.3 | 1.8 | 2.2 | 1.0 | 1.9 | 1.5 | 2.0 | 1.7 | 1.85 | 1.55 | 1.8 | 1.5 | 1.8 | 1.5 | |||
| C. 30-250oC | 3.4 | 3.6 | 3.3 | 2.2 | 3.2 | 1.4 | 2.7 | 2.4 | 3.0 | 2.5 | 2.55 | 2.25 | 2.5 | 2.2 | 2.5 | 2.2 | |||
|
16.
|
Dielectric Strength | Kv/mm | ASTM D-149 | 24 | 16 | 12 | 2 | 2 | Conductive | Conductive | Conductive | ||||||||
|
17.
|
volume Resistivity | ohm cm | ASTM D-257 | 1018 | 1015 | 1015 | 104 | 103 | 107 | 107 | 107 | ||||||||
|
18.
|
Surface Resistivity | ohm | ASTM D-258 | 1015 | 1015 | 1015 | 107 | 106 | 109 | 109 | 1010 | ||||||||
| 19. | Chemical Resistance : PTFE is chemically inert & unaffected by all known chemicals except molten or dissolved alkali metals - Sodium; Potassium; Rubidium; Cesium; Francium & Fluorine gas, certain fluorine compounds & complexes at elevated temperatures. Filled PTFE has inferior chemical resistance depending upon the particular filler. | ||||||||||||||||||
|
*
|
Data quoted
are average values & should not be used as specifications for designing
specifc applications.
|
||||||||||||||||||
|
Powered
by Neonultra
-( Best Solutions For Web Based Content Management)
|